Specifications
3U Traffic Outstation Handbook
667/HB/26568/000 Page 183 Issue 15
CODE
MAJOR
INDEX
MINOR
INDEX
DATA
RANGE DESCRIPTION AND REMARKS
ACCESS
LEVEL
TMP
(PB680
issue 5
or later)
1 - 64
flag no.
- 0 - 1
‘Temp’ Flags used by OMCU
conditioning.
Flags can be changed to control
conditioning operations (where
configured on the OMCU).
Maint
TOD
(PB680
issue 5
or later)
- - time
format
TOD displays day, date and time.
e.g.
TOD: Thu 25-JUN-98 15:53:46
TOD=THU sets the day
TOD=25JUN98 sets the date
TOD=15:55:00 sets the time
Maint
XXC
- -
-
Switch HANDSET to 0141
Controller
Note: Not usable via Remote
Handset
open
XXM
OR
‘
MOVA’
- - -
Switch HANDSET to MOVA
Note: Not usable via Remote
Handset or while connected to the
controller (use XXO first)
open
XXO
- - -
Switch HANDSET to OMCU
Note: Not usable via Remote
Handset. Use ‘FI’ from the MOVA
menu after XXM, not XXO.
open