Specifications
3U Traffic Outstation Handbook
667/HB/26568/000 Page 190 Issue 15
11.10 BUS CONFIGURATION COMMAND TABLE
Code
Major
Index
Minor
Index
Data
Range Description
Access
Level
JID
- - 0 - 9
and
<space>
Junction ID: The ID can only be set
if the OMCU is unconfigured (forced
by INI=1). 16 digits maximum,
including the <space> character.
Maint
BID
For
TCSU
Beacon
- 0 - 15
beacon
list
entry
number
0 - FF
Beacon ID:
1-F = RS485 Beacon ID number.
10-FF = Beacon ID number used for
contact or conditioning input.
0 = Not configured.
Maint
BID
for
SIETAG
Reader
- 0 – 11
serial
port
number
12 - 15
not
used
0 - FF
SIETAG Reader ID:
1-F = Assign this Reader ID to the
RS485 serial port (index). There are
4 serial ports for each I/O board
address.
10-FF = Reserved for indicating loop
no. on multiplexed SIETAG reader
0 = Not configured.
Maint
SRC
- 0 - 15
as BID
0 - 255
Message Source:
99 = any RS485 serial channel.
100 = conditioning input bit
101 = Single RS485 detection per
bus, within given re-activation time
(See RET, below)
0-95 = contact monitored input line
number
255 = not used
Maint
RET
- - 0 - 300
Re-activation Time:
0-300 = If a vehicle is re-detected
within this time (in seconds), then
the second detection is ignored. This
is only applied to the 16 most recent
vehicles detected at the site.
Maint
BFT
- 0 - 15
as BID
0 - 255
Bus DFM Fault Time:
1-255 = The beacon/reader is
reported faulty if no priority vehicle is
detected for this number of hours.
Reported OK on the next detection.
Covers both RS485 and contact type
inputs.
0 = no fault monitoring
Maint
BFO
- - 0 - 255
Bus DFM Fault Output:
0 - 15 = output on i/o board 0
16 - 31 = output on i/o board 1
32 - 47 = output on i/o board 2
255 = no DFM output configured
Maint