Specifications

3U Traffic Outstation Handbook
667/HB/26568/000 Page 195 Issue 15
Code
Major
Index
Minor
Index
Data
Range Description
Access
Level
ARM
- - 0 - 2
Area Mode:
0 = no area filtering applied
1 = ZONE mode: discard vehicle
message if area field is not equal to
Area Value
2 = PRIORITY mode: discard vehicle
message if area field is less than
Area Value
Maint
ARV
- - 0 - F
Area Value:
0-F = Sets either the zone or priority
level for vehicle message filtering,
depending on Area Mode.
Maint
TAF
- - 1 - 3
Tag Format:
1 = Only Siemens encrypted tags
are accepted - others are filtered
out, but still logged.
2 = Only unencrypted tags are
accepted
3 = Both encrypted and unencrypted
tags are accepted (default).
Maint
11.11 Bus Config Notes
All configuration commands take effect as soon as they are entered, except for POC.
The POC command changes the RAM data, but the hardware serial ports are not re-
configured until the POS command is used or the OMCU is powered off then on.
When the handset connection is terminated, system log entry(s) are created
indicating the changed area(s), with change codes allocated to each handset
command used, as follows:
0 = BID, SRC, ASS
1 = MAP, ACT
2 = POC, POS
3 = BFT, BFO, BFR
4 = LAN
5 = LDV
6 = RCI, RCR, RCD, RTO
7 = RET
8 = CUS, ARM, ARV, TAF, DFA
Thus a change to all the data in the output association list will only result in a single
log entry.