Specifications

3U Traffic Outstation Handbook
667/HB/26568/000 Page 200 Issue 15
11.14 DUSC COMMAND TABLE
11.14.1 CLF Operating Commands
CODE
MAJOR
INDEX
MINOR
INDEX
DATA
RANGE DESCRIPTION AND REMARKS
ACCESS
LEVEL
APL
- - CLF
plan
0 - 15
or
Isolate
255
Active CLF Plan is displayed. Use
RPL to request a different plan or
Isolate.
NOTE: When CLF is isolated due
to fault this command still
indicates the requested plan, even
though it’s not running CLF.
RO
CCP
- - 1
Call Current Plan i.e. when CCP=1
is entered, the OMCU rescans the
timetable and re-establishes the
current plan (if any) and
timeswitch events (if any). Used to
restore the OMCU back to normal
operation after an RPL has been
used.
Maint
CCT
- - 0 - 255
secs
Current Cycle Time shows the
incrementing cycle time for the
CLF plan which is currently
running.
RO
CGR
- Stream
0 - 31
CLF
group
0 - 31
Current CLF Group is displayed
for the specified stream.
RO
CGT
- Stream
0 - 31
0 - 255
secs
Current CLF Group Time
remaining counting down to the
end of the current group i.e. how
long before the next group is due
to start.
RO
CID
- - <text>
CLF Data Set Identity:
This identity number/text is used
to check which CLF data set is
currently loaded into the OMCU
working store.
RO
COD
- BUS/
MOVA
I/O
board
No (0 –
2)
0 - 2
Copy Detectors to Outputs on this
board:
0 = Allow normal control of outputs
(e.g. by CLF facility).
1 = Copy the state of the first 16
detector inputs over to the 16
outputs on this BUS/MOVA I/O
board
2 = Copy the inverted state of the
first 16 detector inputs over to the
16 outputs on this BUS/MOVA I/O
board
Maint