Specifications

3U Traffic Outstation Handbook
667/HB/26568/000 Page 203 Issue 15
11.14.2 Accessing CLF Configuration Data Commands
CODE
MAJOR
INDEX
MINOR
INDEX
DATA
RANGE DESCRIPTION AND REMARKS
ACCESS
LEVEL
ACF
- - 0 - 1
CLF
Action on Compliance Fail.
This is the action that is performed
when the OMCU detects a
compliance failure.
0 = isolate mode
1 = continue normal CLF output
control
RO
CAO
Action
number
0 - 31
0 - 3 0 - 255
CLF Action Outputs.
Displays a pair of port numbers
and masks identifying the output
ports and the CLF outputs on a
BUS MOVA IO board driven by
the specified action.
Minor index=0–port A (0-3)
Minor index=1–port A mask(0-FF)
Minor index=2–port B (0-3)
Minor index=3–port B mask(0-FF)
NB: Ports 0 & 1 are on the 1
st
board, ports 2 & 3 are on the 2
nd
board.
RO
CCC
- - 0 - 255
secs
CLF Compliance Fail Clearance
Time.
This is the time that a confirm
input condition must be present
(may be across instances of the
same group action) before a
compliance fault clearance is
raised.
RO
CCF
- - 0 - 255
secs
CLF Compliance Fail Time.
This is the time that a confirm
input condition must be absent
(within the context of a single
group action) before a compliance
fault is raised.
RO
CEC
- Action
number
0 - 31
0 - 1
CLF Enable Compliance.
This displays an indication of
whether compliance checking is
enabled for a group action.
0 = disabled
1 = enabled
RO
IFA
Influence
set
0 – 15
CLF
group
0 - 31
Action
number
0 - 31
InFluence Action number i.e.
which action (and thus which
stream) does this group introduce
in the specified influence set.
RO