Specifications
3U Traffic Outstation Handbook
667/HB/26568/000 Page 59 Issue 15
Figure 13 - Current Sensor Connection
Berg Mini-Latch
Housing
Polarisation Pip
V
oltage
Monitoring
Transformer
Input on I/O
Board 1
First Current Input on I/O Board 1
(Second Current Input on Boards 2 & 3)
To
Lamp
Supply
From
Controller
Output
R
A
To
Lamps
G
(In this example the Output
being monitored is a
3 Aspect Vehicle Phase)
Red Spot Marking on Current
Sensor must point in the
direction shown
34
33
1
2
End Connector Socket
Positions Not Used at
both ends
White
Wire
Orange
Wire
Red Wire Must
be Connected to
Top of Connector
Current Sensor
V
oltage Monitor
Transformer
For more details see 667/GA/26580/000 sheet 2 in Appendix B . The current sensor
should be mechanically secured by passing a TYWRAP or equivalent through the
sensor hole and around a suitable fixing point.
The sensors may produce a high voltage when current is passed
through the core if they are not terminated into an I/O Board.
Caution