Specifications
Station view Nur für den internen Gebrauch
A31003-H3590-M100-5-76A9, 11/2011
7-14 HiPath 3000 Manager E, Administrator Documentation
station.fm
Station Parameters
Brazil: until SMR_K Rel 2.2:
– Templates 1. SLA Default template OPS short:
Flash_min 80 ms, Flash_max 120 ms -> Flash time 80 ms – 200 ms
– Templates 15. SLA, OPS long:
Flash_min 100 ms, Flash_max 700 ms -> Flash time 100 ms – 800 ms
– Templates 16. SLA, ONS short:
Flash_min 70 ms, Flash_max 280 ms -> Flash time 70 ms – 350 ms
– Templates 17. SLA, ONS long:
Flash_min 100 ms, Flash_max 750 ms -> Flash time 100 ms – 850 ms
As of SMR_L Rel 2.2 to HiPath 3000 V1.2/Hicom 150 H V1.2:
– Templates 1. SLA Default template OPS short:
Flash_min 70 ms, Flash_max 280 ms -> Flash time 70 ms – 350 ms
– Templates 15. SLA, OPS long:
Flash_min 100 ms, Flash_max 700 ms -> Flash time 100 ms – 800 ms
– Templates 16. SLA, ONS short:
Flash_min 80 ms, Flash_max 120 ms -> Flash time 80 ms – 200 ms
– Templates 17. SLA, ONS long:
Flash_min 100 ms, Flash_max 750 ms -> Flash time 100 ms – 850 ms
As of HiPath 3000 V1.2/Hicom 150 H V1.2:
– Templates 1. SLA Default template OPS short:
Flash_min 70 ms, Flash_max 280 ms -> Flash time 70 ms – 350 ms
Impedance : 900 Ohm
– Templates 15. SLA, OPS long:
Flash_min 100 ms, Flash_max 750 ms -> Flash time 100 ms – 850 ms
Impedance : 900 Ohm
– Templates 16. SLA, ONS short:
Flash_min 70 ms, Flash_max 280 ms -> Flash time 70 ms – 350 ms
Impedance : 600 Ohm
– Templates 17. SLA, ONS long:
Flash_min 100 ms, Flash_max 750 ms -> Flash time 100 ms – 850 ms
Impedance : 600 Ohm
USA: – OPS short and OPS long line:
Input impedance Zr = 600 Ohm
Simulation impedance Zn = 350 Ohm + 1000 Ohm || 210 nF
– ONS short and ONS long:
Input impedance Zr = 600 Ohm
Simulation impedance Zn = 600 Ohm