Specifications
file.fm
A31003-H3590-M100-5-76A9, 11/2011
HiPath 3000 Manager E, Administrator Documentation
8-31
Nur für den internen Gebrauch File Menu
Transfer
When Delta mode is active, only the changes made since the last Read database are written
into the communication system. If, for example, only a station name is changed, then the trans-
mission time is drastically reduced. In order to determine the delta data, the loaded/active CDB
is compared with the lastload.kds file, which is automatically created and stored on the hard
disk whenever the CDB is read.
Following every successful delta transmission, a log file is created in which the transmitted data
is recorded. A dialog box is displayed to allow you to specify the name of the log file. If no name
is explicitly specified for the log file, a log file named delta.log is generated automatically. The
Log file contains a paragraph in its header in which the compared customer database names
and the creation data are listed. The creation date of the reference customer database is the
date on which the customer database is stored on the hard disk. The creation date of the delta
customer database is the PC time at which the delta transmission was triggered.
Call charges
Activating the Call charges option causes the contents of a particular memory area (RDI =
ReaD or Init) of the communication system to be overwritten by the customer database. This
data contains values that can be only read or initialized.
It makes sense to select this field when exchanging the motherboard so that all data can be
completely taken over or when resetting the following data:
– Call charges
– Counter for the features activated in the communication system
– Station code lock
The following data is also overwritten:
– External call forwarding destinations
– activated call forwarding by station
– Messages sent (message waiting)
– Call forwarding destinations
– Codeword for enabling the mobile telephone
– Cordless base station data
7
If the database was manually stored or was stored by the communication system by
means of the automatic store function (see Program options General), it can no long-
er be loaded from the PC into the communication system in Delta mode. If you use
Delta mode, the changes that you made before you saved will not be transferred.
Only the customer database that is currently loaded in the communication system
should be transmitted. An older customer database may not be transmitted into the
communication system in this manner.