Specifications

Introduction Nur für den internen Gebrauch
A31003-H3590-M100-5-76A9, 11/2011
1-8 HiPath 3000 Manager E, Administrator Documentation
intro.fm
Basic Functions
1.3.1 Read/write database
General Procedure
1. The configuration of the communication system is read via the menu item File/Transfer/
Communication/Read/write database/System -> PC and is then stored as the customer
database in your PC’s main memory.
2. This customer database can now be administered using the Settings menu and can also
be stored on the hard disk for later use.
3. In order to enable the implemented settings, the database is transferred back to the com-
munication system via the menu item PC -> System.
Delta mode
When Delta mode is activated, only changes made since the customer database was last
downloaded are written to the communication system. If, for example, only a station name is
changed, then the transmission time is drastically reduced.
To determine the delta data, the program compares the loaded customer database with the file
lastload.kds, which is automatically created after every transfer from the System -> PC and
is stored on the hard disk.
>
The transfer from the PC -> System overwrites all previous communication system
settings.
See also:
Section 8.19, “Transfer”, on page 8-25
Section 8.19.1, “Transfer | Communication”, on page 8-26