Specifications

Settings Menu Nur für den internen Gebrauch
A31003-H3590-M100-5-76A9, 11/2011
9-48 HiPath 3000 Manager E, Administrator Documentation
settings025.fm
Settings | Cordless (Not in the USA)
9.3.4 Cordless | Base station
Base station offers an overview of the connected base stations to the plugged cordless cards
(SLC, SLUC).
9.3.4.1 Table
Settings | Cordless | Base station
Slot Slot in which the cordless card is
plugged. Slot 2 is displayed for the
mainboard (SLUC).
-
Type Type of the base station (BS).
If no base station is connected, No
Port is displayed.
For an SLC card, the station type
is just displayed.
For an SLUC card, the station
type can be selected. If the type of
No Port is changed to BS3, 12
mobile telephones and one SLC
network line are created at the
first setup.
Master port
Additional port 1
Additional port 2
For an SLC card, the ports to which
the base station is connected are dis-
played.
For an SLUC card, all ports with the
connected terminal devices are dis-
played.