Specifications

Settings Menu Nur für den internen Gebrauch
A31003-H3590-M100-5-76A9, 11/2011
9-64 HiPath 3000 Manager E, Administrator Documentation
settings03.fm
Settings | Lines/networking
This flag must be turned on if an analog DID card (TMDID) is used. This flag switches a DTMF
receiver to the trunk to detect the DTMF signals if analog DID is implemented for the trunk. This
flag can also be used for analog Ground/Loop start Lines. In that case the DTMF information
transmitted by the calling party will be detected and a switching function can be realized. To
activate an announcement, an announcement device can be configured via Announcement
(Announcement prior to answer).
Trunk supervision flag
With this flag set and if there is no dial tone after trunk seizure for a particular analog line, the
communication system makes that line inactive.
If Trunk supervision is activated, this trunk is taken out of operation if there is no dial tone after
seizure. Thereafter, the communication system checks at cyclical intervals to see whether a
dial tone is once again present. When it is, the line is put back into operation.
Ringback protection flag (for Brazil only)
Lets the central office know that ringback calls should not be supported.
There are two corresponding timers for this feature, Time for activation/deactivation of NSI
rel. for ringback prot. (BRAS) (see Time parameters).
Silent-Reversal flag (not in the USA)
Silent reversal on MSI trunk at call start and end via the central office for precise call detail re-
cording. Is required only in the following countries: AUS, CHN, IND, MAL, PHI, THA, SIN, IDS,
IM (Vietnam, Hong Kong, Myanmar).
For IM countries with silent reversal, the silent reversal debounce timer in the MSI port tem-
plates is not set as the default and must be set to 200 ms.
Charge module plugged in/Activated flag (not in USA)
This flag is used to notify the communication system that a charge module is plugged in. The
charge module is integrated on the TM2LP board (in the HiPath 3800). In order to be able to
receive charges via MSI, the flag Charge module activated must be set in this case.
As a result, other input impedances and second ringer impedances are set for the correspond-
ing port.
For the TML8W, the settings short/long trunk and with/without charge data module should al-
ways be made for at least four ports. Otherwise, they are not applied, even when these ports
are not connected or are disabled in the system.
Activating the Charge module activated flag for the first trunk on the TMANI/TLANI boards
allows call charge recording to be performed on all trunks on the boards.