Specifications

Settings Menu Nur für den internen Gebrauch
A31003-H3590-M100-5-76A9, 11/2011
9-180 HiPath 3000 Manager E, Administrator Documentation
settings07.fm
Settings | System Parameters
Euro impedance
In Europe, when this flag is activated Euro impedance is set as follows:
Different PhoneMail messages Day/Night
This flag can be used with Phonemail systems to activate different Phonemail announcements
for a subscriber by sending different call numbers for that subscriber to the Phonemail system.
In the default setting (flag is not set), the call number of the dialed station is always sent to the
Phonemail system. If the flag is set, the call number of the first station entered in the CFW (Call
Forwarding) table is always sent to the Phonemail system if this number is a station number or
group number. Virtual port numbers can also be used.
In addition, different RNA tables for Day/Night must be set up for a station.
Example 1:
Extension 110 is called
Day service call dest. list 1 and Night service call dest. list 2
350 is the hunt group for Phonemail
When the flag is set, the call numbers 110 and 120 are sent to the Phonemail system for Day
and Night service, respectively.
Example 2:
Extension 110 is called
Day service call dest. list 1 and Night service call dest. list e
350 is the hunt group for Phonemail
Regardless of whether or not the flag is set, the call number 110 is sent to the Phonemail sys-
tem during Day and Night service.
SLA TLA
Input impedance 270 Ohm + 750 Ohm || 150 nF 270 Ohm + 750 Ohm || 150 nF
Second ringer impedance 270 Ohm + 750 Ohm || 150 nF 270 Ohm + 750 Ohm || 150 nF
Rel. level A/D 0 dBr -6 dBr
Rel. level D/A -7 dBr -1 dBr
No. Dest 1 Dest 2 Dest Dest Cycles SR Type RNA
1 * 350 3 immediate
2 120 350 3 immediate
No. Dest 1 Dest 2 Dest 3 Dest 4 Cycles SR Type RNA
1 351 350 3 immediate
2 351 350 3 immediate