Specifications

settings07.fm
A31003-H3590-M100-5-76A9, 11/2011
HiPath 3000 Manager E, Administrator Documentation
9-221
Nur für den internen Gebrauch Settings Menu
Settings | System Parameters
Callback delay time
This timer is started, if a subscriber changes into idle.
Once this time has expired, a check is made to see
whether automatic callback is to be implemented. This
gives the user an opportunity to make further calls.
Idle 0 – 60 s
Length of call back
In case an automatic callback is not answered within this
time, the call is finished and the callback is postponed.
Call signaling of
callback
15 – 60 s
Intercept time for automatic recall
If an automatic recall of a blind transfer is not answered
within this time, it is intercepted to the attendant console,
if this intercept criterion has been configured.
Automatic recall 20 – 600 s
Calling time transfer before answer on busy station
If a blind transfer (to a busy station) is not answered with-
in this time, the recall is forwarded to the extension that
transferred the call.
30 – 600 s
End-of-selection for incomplete dialing (Austria)
Supervisory timer for direct inward dialing. In case no se-
lection occurs during this time, the direct inward dialing is
recognized as incomplete or as no dialing. (Austria only)
Direct inward di-
aling
10 – 30 s
End-of-selection time (no dialing)
In case selection is not started within a certain time, an
end-of-selection is automatically generated.
Direct inward di-
aling
5 – 15 s
Time for parking + change to hold
Reactivation of a parked call must occur within a timeout.
In case the parked call is not answered (resumed) within
this time, the station, which has parked the call, will be re-
called. With the automatic recall, the hold status reverts
to an active status.
Common Hold 60 – 255 s
End-of-selection for incomplete dialing
In case dialing is not continued within a certain time, an
end-of-selection is automatically generated.
10 – 20 s
Time parameters Effective in the
CP status:
Timer range