Specifications
settings07.fm
A31003-H3590-M100-5-76A9, 11/2011
HiPath 3000 Manager E, Administrator Documentation
9-227
Nur für den internen Gebrauch Settings Menu
Settings | System Parameters
Table for transit monitoring
Error signaling interval
The error signaling time defines an interval in the value
range 1 to 15 minutes. Decimal places are rounded up to
full minutes, values under 1 min. or above 15 min. are
evaluated as 15 min.
The current Class B error entered in the event log is
transferred cyclically to the remote center when the inter-
val has elapsed.
60 – 900 s
Delay of busy signaling messages
For the Inter-system busy signaling feature (see QSIG
features (not in the USA)), the statuses of selected sta-
tions are sent to the central communication system via
QSIG. Message sending can be delayed using this timer,
in order to avoid bottlenecks at the QSIG interface. The
timer is started when a message is sent. The next mes-
sage is not sent until the timer has expired.
HiPath 4000 Network: Early DMC
This timer defines when the DMC (Direct Media Connec-
tion) procedure is started. This timer is started when an
alerting message is received via the network trunk. This
timer is only used for fine adjustment so that switchover
can be implemented as far as possible when tones are
not being output.
0
A side B side Monitoring timer
MSI MSI yes
MSI MSI with silent reversal yes
MSI ISDN no
MSI CorNet (int.) no
MSI CorNet (ext.) yes
Analog trunk with silent reversal Analog trunk yes
Analog trunk with silent reversal Analog trunk with silent reversal no
Analog trunk with silent reversal E&M no
Time parameters Effective in the
CP status:
Timer range