Specifications
settings07.fm
A31003-H3590-M100-5-76A9, 11/2011
HiPath 3000 Manager E, Administrator Documentation
9-229
Nur für den internen Gebrauch Settings Menu
Settings | System Parameters
9.8.11 Tones and ring types
The Tones and ring types parameters are set to industry standards by default and can only
be changed with "Development" privileges. Apart from a few exceptions, the fields are grayed
out here.
9.8.11.1 Tones/ring types table
The tone or ring type that is to be displayed or changed is selected from this list. Depending on
which item is selected, different fields are displayed.
9.8.11.2 Area: Settings
Continuous tone
For a continuous tone, rather than a sequence of tones, the Continuous tone flag must be set.
Tone sequence
This setting makes the distinction between a tone sequence that is repeated at intervals and
a one-off tone sequence.
Attenuation index
The Attenuation index allows you to change the volume level for the various tones. Each tone
can have its own volume level. For example, the warning tone louder can be set louder than the
busy signal. The range is from zero to three with the volume becoming louder as the numbers
get higher.
Frequency Indices (F1, F2, F3)
The max. 3 generators that generate the individual frequencies are entered here.
Mode
The frequencies F1, F2, F3 that the individual pulses consist of are specified here.
Pulse
The timeouts for pulses and pauses are entered in these fields in milliseconds.
Settings | System Parameters | Tones and ring types