Specifications

Settings Menu Nur für den internen Gebrauch
A31003-H3590-M100-5-76A9, 11/2011
9-250 HiPath 3000 Manager E, Administrator Documentation
settings08.fm
Settings | Auxiliary equipment
9.9.6 Sensors
Sensors is used to configure the control inputs which trigger the corresponding functions in the
communication system.
9.9.6.1 Sensor list table
The sensors to be administered are listed in the list.
9.9.6.2 Area: Sensor
Sensor type
The sensors can be assigned to different types in accordance with the above functionalities.
Entry in Error History
Allows you to select whether or not error 1/19 is to be entered in the error history.
Only active for the sensor type ALARM.
Destination call number
An associated a/b port is programmable for the sensors. This port is called by the communica-
tion system once a setup signal has been received. The calling party then overrides this con-
nection. A recorded announcement can be activated via an answering machine connected to
this port, which informs the dialed station of the response of the sensor. An a/b port pro-
grammed in this way cannot be contacted from the outside.
If an external phone number or an EVM was programmed for a sensor instead of an a/b port,
the connection is established, but no acoustic information is transmitted regarding the sensor
response.
If the phone number is external, the called station can at least – if CLIP is active– see the origin
of the call.
Settings | Auxiliary equipment | Sensors
>
Important: This feature is not implemented for an external phone number and an
EVM.