Specifications

Settings Menu Nur für den internen Gebrauch
A31003-H3590-M100-5-76A9, 11/2011
9-304 HiPath 3000 Manager E, Administrator Documentation
settings09.fm
Settings | Network
9.10.3.3 Area: Multiple Trap
If error events are configured for Log+multiple trap in the Trap Flags table, then these errors
are signaled multiple times per SNMP trap when a corresponding error event occurs. The num-
ber of times a trap is signaled is specified in Multiple Trap.
9.10.3.4 Area: SNMP Flags
Enable SNMP
This option activates the SNMP (Simple Network Management Protocol) of the communication
system.
CDR Notification Traps
This option is used to generate a trap for CDR applications when the call charge output stack
exceeds a threshold value. Please note, however, that this applies only to CDR applications that
read the call charge stack via TFTP
Port Status Notification Traps
This option causes a trap to be generated whenever a change in the hardware occurs (e.g.,
when cards/telephones are plugged or unplugged). These traps are evaluated by the HiPath
FM to update the hardware tables.
Value This column can be edited, and it determines what should happen when
a Class B error occurs in the communication system:
Log = The error is saved only in the error history, which can be
read per maintenance.
Log+trap = The error is saved in the error history and is also
sent as an SNMP error message (trap).
Log+multiple trap = The error is saved in the error history and
is sent multiple times as an SNMP error message (trap).
See also
Section 9.10, “Settings | Network”, on page 9-294
HiPath 3000/5000 Feature Description, LAN Network