Specifications
options.fm
A31003-H3590-M100-5-76A9, 11/2011
HiPath 3000 Manager E, Administrator Documentation
12-9
Nur für den internen Gebrauch Options Menu
Program Options
Reset
The initialization command for the modem is entered here.
Init
The modem command that sets the modem to the required mode is entered here. The standard
modem commands are preset. If you select one of the modem types listed in the Modem types
list, this parameter will be set automatically. If you select the New Modem entry, you must enter
the appropriate init string manually.
If the modem is to create a connection over a communications server, the parameter X3 in the
init string must be included. It causes the modem to make a connection without a continuous
dial tone.
12.1.3.3 Area: Modem answer
Connection
This is the modem answer that is expected after a successful connection setup.
Busy
This is the modem answer that is expected if no connection is set up. As a rule, the default value
does not need to be modified.
12.1.3.4 Area: Timers
Dialing
This parameter defines how long the modem will wait for the connection before it redials. This
value depends on the basic configuration of the modem and the dialing method. Valid values
range from 0 to 999 seconds. The default, appropriate for most circumstances, is 40 seconds.
Redial Pause
This parameter defines the length of the pause between dialing attempts. Valid values range
from 0 to 999 seconds. The default is 10 seconds.
>
Automatic answering must be deactivated for the PC modem (the factory setting of
fax modems is usually set to automatic answering by default).
Depending on the modem installed, the init string should changed to AT&FS0=0.