Specifications

allserve.fm
A31003-H3590-M100-5-76A9, 11/2011
HiPath 3000 Manager E, Administrator Documentation
4-27
Nur für den internen Gebrauch Starting up HiPath 5000 RSM/AllServe
Central Busy Signaling with Attendant P
4.7 Central Busy Signaling with Attendant P
This section describes which steps are required to set up central busy signaling in connection
with Attendant P.
Sample configuration
No settings are needed in the HG 1500 cards because, among other things, the CAR ta-
bles in the HG 1500 cards are created automatically.
In this description, Attendant P is operated via an RS232 connection.
The subnode busy signaling of card tab 3-16 differs from that of the main node, which uses
card tabs 1 and 2. Different colors can be set up in the Configuration Manager to indicate
the states “internal busy”, “external busy” and “station is ringing”. In the case of the subn-
ode card tab 3-16, the color selected for “internal busy” is the same as the color for “station
is ringing”.
Attendant P must also function when the server is shut down. In other words, none of the
components associated with other servers such as the Feature Server, TAPI, etc., affect
the functionality of Attendant P.
HiPath
5000
HiPath
3000
Node 2
HiPath
3000
Node 3
HiPath
3000
Node 4
Trk grp 16
Trk grp 16
Trk grp 16
9782 PABX no.
9783 PABX no.
9784
System number
HiPath
3000
Node 1
9781 PABX no.
Trk gr p 16
ATT
P
System tele-
phone with
Data Adapter
Trk Gr p. 64