Specifications

3000sb2.fm
P31003-H3560-X100-1-7618, 09/05
HiPath 3000/5000 V6.0, System Description
2-89
For internal use only
HiPath 3000 System Overview
HiPath 3500
Interfaces
Eight U
P0/E
(digital subscriber line interfaces)
Up to seven BS3/1 base stations can be connected directly for HiPath Cordless Office.
Four T/Rs (analog subscriber line interfaces)
For Australia only: The T/R interfaces supply a ring voltage of 35 V
eff
. Depending on the
terminals connected, we cannot exclude the possibility of errors occurring during ringing
state.
Two S
0
interfaces (trunk or subscriber or fixed connection)
One V.24 interface
2.9.3.2 UPSC-DR
Introduction
This board combines the power supply and battery management functions. No other compo-
nents are required if operated as a power supply. To maintain short-term battery emergency
operation after a power failure, that is, to use uninterruptible power supply functions, you must
also connect a battery pack.
An EPSU2-R external power supply must be used if the total number of U
P0/E
stations, analog
stations, and stations connected using adapters is greater than 72.
Additional power can be made available by connecting the external EPSU2-R power supply
(see Section 2.9.6) To do this, connect the DC port on the EPSU2-R to the special –48 Vdc in-
put on the UPSC-DR. The UPSC-DR’s internal -48-V output is deactivated when the external
power supply is connected.
Technical specifications
Nominal voltage range: 100 Vac - 240 Vac
Nominal frequency: 50 Hz - 60 Hz
Ring generator: 75 Vac, 20/25/50 Hz
Partial voltages: +5 Vdc, –48 V
Battery charger: 4 x 12 V (40.8 V-55.2 V)
Power consumption: approx. 180 W