Specifications

HiPath 3000 System Overview For internal use only
P31003-H3560-X100-1-7618, 09/05
2-92 HiPath 3000/5000 V6.0, System Description
3000sb2.fm
HiPath 3500
2.9.4.2 Trunk Boards
Table 2-40 Trunk Boards for HiPath 3500
Board
Name
Capacity Cou
ntry
Type/Description
Ports per board
B channels per board
Max. number of
boards per system
ROW
U.S.
STLS4R 4 8 #
1
1 The maximum number is calculated on the basis of the system-specific capacity limits in Table 2-1.
x x Board for ISDN basic access. Permits configuration of ISDN
trunks, tie trunks, and subscribers (no feeding) on the same
board.
TLA4R 4 #
1
x - Trunk board for analog lines including ALUM and call meter-
ing receiving equipment board
TMGL4R 4 #
1
- x Trunk board for analog lines
TS2R 30 30 1 x - In HiPath 3000/HiPath 5000 V5.0 and later, the B channels
in the TS2R board are subject to license. Consequently, the
TS2R board S30810-K2913-Z300 has been assigned a new
hardware identification code. The new code prevents the
board from being used in earlier versions. Functionality and
layout of the board have not been changed.
TST1 1 24 1 - x PRI board