Specifications

3000sb2.fm
P31003-H3560-X100-1-7618, 09/05
HiPath 3000/5000 V6.0, System Description
2-95
For internal use only
HiPath 3000 System Overview
HiPath 3500
2.9.6 Additional Power Supply from the EPSU2-R
An EPSU2-R external power supply must be used if the total number of U
P0/E
stations, analog
stations, and stations connected using adapters is greater than 72.
Additional power can be made available by connecting the external EPSU2-R power supply.
To do this, connect the DC port on the EPSU2-R to the special –48 Vdc input on the UPSC-
DR. The UPSC-DR’s internal -48-V output is deactivated when the external power supply is
connected.
The additional EPSU2-R external power supply unit is installed in the ECR.
EPSU2-R technical specifications
Table 2-43 EPSU2-R - Technical Specifications
EPSU2-R
S30122-K7221-X900
Scope of delivery EPSU2-R AC/DC converter without batteries
Operating instructions
Network connection cable from ECR to HiPath
3500 or HiPath 3300: C39195-Z7001-C14
AC power 100 - 240 V ac
Frequency range 47 to 63 Hz
Connected output 200 W
Output power consumption/nominal
output
140 W
Mains/nominal voltage 54.2 V
UPS batteries V39113-W5123-E891
Batteries are not included in the scope of supply and
must be ordered separately.