Specifications

3000sb2.fm
P31003-H3560-X100-1-7618, 09/05
HiPath 3000/5000 V6.0, System Description
2-101
For internal use only
HiPath 3000 System Overview
HiPath 3300
Bridging times
The following table lists the maximum bridging times (battery operation in case of power
failure) available with four batteries V39113-W5123-E891 (4 x 12 V/7 Ah batteries).
2.10.3.3 LIM
The LAN Interface Module (LIM - S30807-Q6930-X) is an optional plug-in card for all HiPath
3000 central control boards (see also Section 4.4).
The board provides an Ethernet (10BaseT/10 Mbps) LAN connection via an 8-pin RJ45 jack.
The LIM module can be used for administration via HiPath 3000 Manager E and for CTI func-
tions (TAPI 120 V2.0). However, bear in mind that the number of BHCAs (Busy Hour Call At-
tempts = number of connection attempts during busy traffic hours) is restricted to 400 at a max-
imum of six TAPI ports. The use of "power dialers" is not approved.
You cannot operate the LIM module and a HG 1500 board simultaneously in one system.
Table 2-45 UPSC-DR - Bridging Times with four Batteries V39113-W5123-E891 (4 x
12 V/7 Ah Batteries)
System Power supply
unit
Load levels Maximum bridg-
ing time
HiPath 3300 UPSC-DR Normal output load = 5 V/3 A;
–48 V/0.5 A; ringing approx. 2 VA
7h 30min
Measurement conditions:
All measurements were performed at a room temperature of approximately 23 °C
(73.4 °F).
The batteries were fully charged when the measurement was started.