Specifications
3000sb2.fm
P31003-H3560-X100-1-7618, 09/05
HiPath 3000/5000 V6.0, System Description
2-111
For internal use only
HiPath 3000 System Overview
HiPath Cordless Office
2.12 HiPath Cordless Office
2.12.1 Introduction
For Version 1.2 and later of HiPath 3000, HiPath Cordless Office can be used on all systems of
this product line.
Direct connection
The BS3/1 (S30807-H5482-X) and BS4 (S30807-U5491-X) base stations can be connected di-
rectly to the U
P0/E
interfaces on the central control boards in the HiPath 3550, HiPath 3350, Hi-
Path 3500, and HiPath 3300. The connection must be made via one U
P0/E
interface each. A
mix of base stations of types BS3/1 and BS4 is supported.
To ensure the operation of a maximum of one base station on the central control board’s U
P0/
E
interfaces of the HiPath 3550, HiPath 3350, HiPath 3500, and HiPath 3300, a BS3/S (X30807-
X5482-X100) single-cell base station can be used. In this case, it is not possible to expand with
additional base stations.
However, base stations cannot be simultaneously connected to the SLC16/SLC16N board and
the CBCC within one HiPath 3550 system.
Connecting cordless boards
Base stations can be connected to the U
P0/E
interfaces of the following cordless boards:
● SLC16 (not BS4) and SLC16N with HiPath 3750, HiPath 3550, and HiPath 3700.
● SLCN in HiPath 3800
A mix of base stations of types BS2/2 (S30807-H5471-X200), BS3/1 (S30807-H5482-X), BS3/
3 (S30807-H5485-X) and BS4 (S30807-U5491-X) may be used on the above cordless boards.
You can install up to four SLC16 or SLC16N boards in HiPath 3750 and HiPath 3700 and up to
four SLCN boards in HiPath 3800. All four boards provide full cordless functionality (roaming
and seamless connection handover) because the radio fields on the cordless boards are syn-
chronized within a single system (see Section 2.12.3).
SLC16 and SLC16N can be used in mixed mode within a HiPath 3750 and HiPath 3700.
The HiPath 3000 product line does not currently support the network-wide handover feature.