2.12.2 System Configuration
The following table indicates the maximum possible system configuration parameters for the
HiPath Cordless Office. It also shows when
CMA or CMS is necessary.
an analog trunk access is possible.
Table 2-51 HiPath Cordless Office - System Configuration for HiPath 3000 V5.0
System
Max. no.
Clock modules
Maximum number of base sta-
tions BS with connection via
1xU
P0/E
Simultaneous
calls per BS
Max. no.
MTs
Analog
trunk access
of the system
SLC16
SLC16N
SLCN
BS3/1
BS3/S
BS2/2
BS3/3
BS4
BS3/1
BS3/S
BS2/2
BS3/3
BS4
HiPath 3350
HiPath 3300
CMS 1 2 8 No
–––CMA– 1 4 8 Yes
–––CMA3 3 44 16 Yes
HiPath 3550
HiPath 3500
CMS 1 2 8 No
–––CMA– 1 4 8 Yes
–––CMA7 7 44 32 Yes
HiPath 3550 1 1 CMS 16 8 8 16 4 8 12 12 64 Yes
HiPath 3750
HiPath 3700
4 4 CMS 64 32 32 64
1
1 Connection is only possible with SLC16N.
4–81212
250 (with
4 SLC16/
SLC16N)
2
2 Up to 128 handsets are possible at an SLC16 or SLC16N.
Yes
HiPath 3800 4 CMS 64 32 32 64 4 8 12 12
250 (with
4 SLCN)
3
3 Up to 128 MTs are possible at an SLCN.
Yes
Comments:
BS2/2 (S30807-H5471-X200) is a base station that supports a maximum of 8 calls when connected using
two U
P0/E
interfaces.
BS3/1 (S30807-H5482-X) is a base station that supports a maximum of 4 calls.
BS3/3 (S30807-H5485-X): is a base station that supports a maximum of 12 calls when connected using
three U
P0/E
interfaces.
BS3/S (X30807-X5482-X100): The BS3/S single-cell base station guarantees the operation of a maximum
of one base station on the U
P0/E
interfaces of the central board. It is not possible to operate additional base
stations.
BS4 (S30807-U5491-X): is a base station that supports a maximum of 12 calls when connected using
three U
P0/E
interfaces. In the case of a direct connection, it is only permitted to make the connection via
one U
P0/E
interface. The B channels in the base station BS4 require a license.
Connection to SLC16 is not possible.