2.12.3 Multi-SLC and Cross-System Networking
Multi-SLC (HiPath 3800, HiPath 3750, HiPath 3700) and system-wide networking (HiPath
3800, HiPath 3750, HiPath 3550, HiPath 3350, HiPath 3700, HiPath 3500, HiPath 3300)
You can install up to four SLC16 or SLC16N boards in HiPath 3750 and HiPath 3700 and up to
four SLCN boards in HiPath 3800. For the total cordless station mobility (roaming and seamless
connection handover) within a system, the radio fields of these cordless boards are synchro-
nized.
The system treats every handset (mobile station) as a corded device. During administration, a
fixed port on the system’s “home cordless board” is assigned to the MT; this is used for ad-
dressing the MT.
As soon as an MT moves into the area of a different radio switching location (“current-location
cordless board”), an extension connection is switched using a DSS1 connection initiated by the
cordless board. The home and current-location cordless boards exchange a networking proto-
col (User-to-User Signaling UUS) over this extension connection to support full mobility (see
Figure 2-27).
This function can be used not only within one system, but also among systems (among nodes)
because the CorNet NQ used for networking supports the UUS protocol (note: for the system-
wide extension connections, you may have to take additional B channels into consideration for
the permanent connection paths (CorNet NQ, see Section 2.12.4). Full mobility is guaranteed
across the various cordless system hops. All handset features (callback, team functions, voice-
mail, etc.) remain intact. The network-wide handover feature is only exception here as it is not
currently supported.
Required B channels
Table 2-52 Required B Channels for Multi-SLC and System-Wide Networking
Mobile telephone (MT) has set
up a connection
Required B
channels
Required B chan-
nels for the home
cordless board
Required B chan-
nels for the cur-
rent-location
cordless board
In the home cordless board range 1 1 –
In the current-location Cordless
board range
32 1
Handover from home to home
cordless board
11 –
Handover from home to current-lo-
cation cordless board
32 1