HiPath Cordless Office
Networked HiPath 3000 systems feature
max. 64 networked systems
accessible using a common station number (roaming among the systems/nodes)
call interruption when changing between systems/nodes
Handover from current-location to
current-location cordless board
5
(temporary)
32
(1 for each cordless
board)
Figure 2-27 Example of an SLC16 Extended Connection in Networked Systems
Table 2-52 Required B Channels for Multi-SLC and System-Wide Networking
Mobile telephone (MT) has set
up a connection
Required B
channels
Required B chan-
nels for the home
cordless board
Required B chan-
nels for the cur-
rent-location
cordless board
BS
SLC16
BS
CorNet-NQ
Home SLC16
SLC16 no. = 1
Call no. = 124
Visitor SLC16
SLC16 no. = 11
Call no. = 128
HiPath 3750
Node ID = 1
HiPath 3550
Node ID = 2
Extension
connection
BS
SLC16
BS
SLC16 no. = 2
Call no. = 141
BS
SLC16
BS
BS = BS2/2, BS3/1 or
BS3/3
A CorNet NQ connection is possible using S
0
or S
2M
lines or IP networking (see HG 1500 Administration