Specifications

3000sb4.fm
P31003-H3560-X100-1-7618, 09/05
HiPath 3000/5000 V6.0, System Description
4-11
For internal use only
HiPath 3000/5000 in the LAN Network
LIM Board for LAN Connection
4.4 LIM Board for LAN Connection
The LIM module allows the cost-effective connection of all HiPath 3000 models in TCP/IP-
based LANs for the central system administration, APS transfer, TeleData Office or HiPath Fault
Management. A 10 MB 10BaseT interface with an RJ45 jack is available for the LAN connec-
tion.
Up to 6 TAPI 120 V2.0 can be operated via the LIM module on HiPath 3000 V4.0 SMR6 or later.
However, a maximum traffic value of 400 BHCA is permitted.
Power dialers are not released for use.
>
Systems which already have a HG 1500 board do not require the use of the LIM
board as the above-mentioned functions are already provided by HG 1500.
The new LIM module replaces the previous LAN interface (Com server or V.24/E
module) for the models Hicom 150 H/E OfficePro/Com/Point.
HiPath 3000/5000
e.g. PC with
HiPath 3000 Manager E
Central Board
LIM
Customer
LAN
e.g. PC for
Network Management
SNMP