Calculating the number of LUNA2 modules required
Depending on the number and type of peripheral boards installed, the number of LUNA2
boards required can be calculated using the following table.
Examples for a single-cabinet system:
a) Basic cabinet with CBSAP and peripheral boards (no STMI2, SLMA or SLCN)
A single LUNA2 can feed one CBSAP and up to four peripheral boards.
A second LUNA2 is required for five or more peripheral boards.
A third LUNA2 can be used as a battery charger or as a redundant LUNA2.
b) Basic cabinet with CBSAP and peripheral boards (with STMI2, SLMA and/or SLCN)
Two LUNA2s are always required to supply a CBSAP, peripheral boards and
STMI2, SLMA and/or SLCN.
A third LUNA2 can be used as a battery charger or as a redundant LUNA2.
Table 2-5 Determining the Number of LUNA2 Boards Required per Cabinet
Number of peripheral
boards per cabinet
STMI2, SLMA and/or
SLCN available
Number of
LUNA2s required
per cabinet
Basic cabinet < 5 No 1
< 5 Yes 2
5No2
5Yes2
Expansion cabi-
net
< 5 No 1
< 5 Yes 2
5No2
5Yes3
10 No 3
10 Yes 3