Specifications

3000sb2.fm
P31003-H3560-X100-1-7618, 09/05
HiPath 3000/5000 V6.0, System Description
2-19
For internal use only
HiPath 3000 System Overview
HiPath 3800
2.2.4.3 LIMS
The LAN Interface Module for SAPP LIMS (S30807-Q6721-X) is an optional plug-in card for
the CBSAP central control board in HiPath 3800.
The board provides two Ethernet (10/100BaseT) LAN connections via two 8-pin RJ45 jacks:
LAN1 (administration via HiPath 3000 Manager E and CTI functions)
LAN2 (not assigned)
The LIMS module can be used for administration via HiPath 3000 Manager E and for CTI func-
tions (TAPI 120 V2.0). However, bear in mind that the number of BHCAs (Busy Hour Call At-
tempts = number of connection attempts during busy traffic hours) is restricted to 400 at a max-
imum of six TAPI ports. The use of "power dialers" is not approved.
You cannot operate the LIMS module and an STMI2 board simultaneously in a HiPath 3800.