Specifications

3000sb2.fm
P31003-H3560-X100-1-7618, 09/05
HiPath 3000/5000 V6.0, System Description
2-29
For internal use only
HiPath 3000 System Overview
HiPath 3750
The illustrations below show the PCM segments (64 time-division multiplex channels each) be-
tween the different HiPath 3750 system configurations.
Single-cabinet system: PCM segments
7
Caution
To guarantee that the system operates without faults or blocking, it is necessary that
you observe the following rules for the configuration of boards:
SLC16, SLC16N
A maximum of one SLC16 or SLC16N per PCM section. If possible, the
SLC16 or SLC16N should remain alone on the PCM segment.
For more information on multi-SLCs, see Multi-SLC and Cross-System Net-
working.
IVML8, IVML24
A maximum of one IVML8 or IVML24 per system.
This board may only be inserted into the slot beside the power supply in the
basic cabinet or in the expansion cabinets.
You may not insert an SLC16 or SLC16N on the PCM segment of the
IVML8 or IVML24.
You may not insert an SLMO24 on the PCM segment of the IVML24.
If there is a TMS2 on the PCM segment of the IVML24, only one board with
up to eight ports is allowed on the free slot.
SLMO24
A maximum of two SLMO24s per PCM segment; the number of connected sta-
tions (hosts (master) and clients (slaves)) may not be more than 64.
Figure 2-8 PCM Segments for a Single-Cabinet System
C
B
C
P
R
0
2
0
3
0
4
0
8
U
P
S
M
0
5
0
6
0
7
"8-slot" cabinets
BC