Specifications
3000sb2.fm
P31003-H3560-X100-1-7618, 09/05
HiPath 3000/5000 V6.0, System Description
2-29
For internal use only
HiPath 3000 System Overview
HiPath 3750
The illustrations below show the PCM segments (64 time-division multiplex channels each) be-
tween the different HiPath 3750 system configurations.
Single-cabinet system: PCM segments
7
Caution
To guarantee that the system operates without faults or blocking, it is necessary that
you observe the following rules for the configuration of boards:
● SLC16, SLC16N
– A maximum of one SLC16 or SLC16N per PCM section. If possible, the
SLC16 or SLC16N should remain alone on the PCM segment.
– For more information on multi-SLCs, see Multi-SLC and Cross-System Net-
working.
● IVML8, IVML24
– A maximum of one IVML8 or IVML24 per system.
– This board may only be inserted into the slot beside the power supply in the
basic cabinet or in the expansion cabinets.
– You may not insert an SLC16 or SLC16N on the PCM segment of the
IVML8 or IVML24.
– You may not insert an SLMO24 on the PCM segment of the IVML24.
– If there is a TMS2 on the PCM segment of the IVML24, only one board with
up to eight ports is allowed on the free slot.
● SLMO24
A maximum of two SLMO24s per PCM segment; the number of connected sta-
tions (hosts (master) and clients (slaves)) may not be more than 64.
Figure 2-8 PCM Segments for a Single-Cabinet System
C
B
C
P
R
0
2
0
3
0
4
0
8
U
P
S
M
0
5
0
6
0
7
"8-slot" cabinets
BC