Specifications

3000sb2.fm
P31003-H3560-X100-1-7618, 09/05
HiPath 3000/5000 V6.0, System Description
2-39
For internal use only
HiPath 3000 System Overview
HiPath 3750
2.3.5.2 Trunk Boards
Table 2-14 Trunk Boards for HiPath 3750
Board
Name
Capacity Cou
ntry
Type/Description
Ports per board
B channels per board
Boards per cabinet
Max. number of
boards per system
ROW
U.S.
TML8W 8 #
1
1 The maximum number is calculated on the basis of the system-specific capacity limits in Table 2-1.
#
1
x - Board with eight ports for connecting loop start trunks.
STMD8 8 16 #
1
#
1
x x Board for ISDN basic access. Permits mixed configu-
ration of ISDN trunks, tie trunks, and subscribers on the
same board.
TMS2 30 30 #
1
6 x - Basic rate interface (BRI) board; can also be used for
tie trunk traffic.
TMST1 24 24 #
1
8 - x ISDN interface board
TMDID 8 #
1
#
1
- x Analog trunk board for direct inward dialing
TMGL8 8 #
1
#
1
- x Analog trunk board (ground/loop start)
TMAMF 8 x - Analog trunk board for direct inward dialing (MFC-R2)