Specifications
HiPath 3000 System Overview For internal use only
P31003-H3560-X100-1-7618, 09/05
2-48 HiPath 3000/5000 V6.0, System Description
3000sb2.fm
HiPath 3550
● Bridging times
The following table lists the maximum bridging times (battery operation in case of power
failure) available with the battery pack S30122-K5928-X (48 V/1.2 Ah).
2.4.3.3 LIM
The LAN Interface Module (LIM - S30807-Q6930-X) is an optional plug-in card for all HiPath
3000 central control boards (see also Section 4.4).
The board provides an Ethernet (10BaseT/10 Mbps) LAN connection via an 8-pin RJ45 jack.
The LIM module can be used for administration via HiPath 3000 Manager E and for CTI func-
tions (TAPI 120 V2.0). However, bear in mind that the number of BHCAs (Busy Hour Call At-
tempts = number of connection attempts during busy traffic hours) is restricted to 400 at a max-
imum of six TAPI ports. The use of "power dialers" is not approved.
You cannot operate the LIM module and a HG 1500 board simultaneously in one system.
Table 2-18 UPSC-D - Bridging Times with Battery Pack S30122-K5928-X (48 V/
1.2 Ah)
System Power sup-
ply unit
Load levels Maximum bridg-
ing time
HiPath 3550 UPSC-D Normal output load 100 % = 5 V/8 A;
–48 V/1.1 A; ringing approx. 4 VA
6 min
HiPath 3550 UPSC-D Normal output load 60 % = 5 V/4.8 A;
–48 V/0.66 A; ringing approx. 2 VA
15 min
HiPath 3550 UPSC-D with
EPSU2
Normal output load 100 % = 5 V/8 A;
–48 V/2.5 A (external via EPSU2);
ringing approx. 4 VA
17 min
Measurement conditions:
● All measurements were performed at a room temperature of approximately 23 °C
(73.4°F).
● The batteries were fully charged when the measurement was started.