Specifications

3000sb2.fm
P31003-H3560-X100-1-7618, 09/05
HiPath 3000/5000 V6.0, System Description
2-49
For internal use only
HiPath 3000 System Overview
HiPath 3550
2.4.4 Peripheral Components
2.4.4.1 Subscriber Line Modules
Table 2-19 Subscriber Line Modules for HiPath 3550
Board
Name
Capacity Cou
ntry
Type/Description
Ports per board
B channels per board
Max. number of
boards per system
ROW
U.S.
4SLA 4 #
1
x - Board for connecting analog stations (a/b, T/R)
8SLA 8 #
1
x x Board for connecting analog stations (a/b, T/R)
16SLA 16 #
1
x - Board for connecting analog stations (a/b, T/R)
HXGS3 2 8 3 x x HG 1500 board for the direct connection of IP workpoint cli-
ents.
IVMS8 8 8 1 x x Board for the integrated voicemail functions of HiPath
Xpressions Compact.
SLU8 8 16 #
1
x x Board for connecting optiPoint 500 and optiset E telephones
(U
P0/E
)
STLS2 2 4 #
1
x - Board for providing ISDN basic rate access.
Configuration of ISDN trunks, tie trunks, and subscribers (no
feeding) on the same board is possible.
STLS4 4 8 #
1
xx
SLA8N 8 1 x - HiPath 3750 board for connecting eight analog stations (a/b,
T/R)
Can be installed in Slot level 5 only
SLA16N 16 1 x x HiPath 3750 board for connecting 16 analog stations (a/b, T/
R)
Can be installed in Slot level 5 only
SLA24N 24 1 x x HiPath 3750 board for connecting 24 analog stations (a/b, T/
R)
Can be installed in Slot level 5 only
SLC16 16 1 x - HiPath 3750 boards for connecting 16 CMI base stations.
Can be installed in Slot level 5 only
SLC16N 16 1 x -