Specifications

HiPath 3000 System Overview For internal use only
P31003-H3560-X100-1-7618, 09/05
2-56 HiPath 3000/5000 V6.0, System Description
3000sb2.fm
HiPath 3550
Battery operation:
Permitted batteries
Manufacturer/type num-
ber
Number of batteries
Size (Ah)
Nominal voltage
Overload protection
CSB/EVX-1270, Hitachi/HP6.5-12, Yuasa/NP6-12, Varta/
Noack 43720303, Sonnenschein/0719143200, Panasonic/
LCR12-7P
4 units, 12 V each
7Ah
48 V (fully charged 54 V, discharge to 44 V)
Melting fuse 5 x 20 mm, 2.5 A/slow-blowing
Nominal current 2.5 A
Overload protection Electronic current limiting circuit
Ambient temperature In buildings, +5 to +45 °C (41 to 113 °F)
Humidity 95%/non-condensing
Cooling Natural convection
Protection IP 21 (DIN 40050)
Housing dimensions (W x D
x H in mm)
250 x 114 x 317
Weight approx. 14.1 kg (incl. batteries) approx. 4.1 kg (without batter-
ies)
Symbol CE
Personal safety, insulation EN60950 and IEC950
Grounding, shielding Protection class 1, output is floating against ground.
Table 2-23 EPSU2 - Technical Specifications
EPSU2
S30122-K7221-X1
EPSU2
S30122-K7221-X2