Specifications

Maintenance Nur für den internen Gebrauch
A31003-H3580-M103-2-76A9, 01-2009
6-44 HiPath 3000/5000 V8 - HG 1500 V8, Administrator Documentation
hg-06.fm
Tra c e s
The Trace Component mask: [Name]is displayed. You can edit the following fields:
Trace Level: Trace levels have a value range from 0 to 9. 0 stands for the least amount, and
9 for the greatest amount of detail. Thus, the higher the number, the more trace information
provided.
Tra c e O n : Activate this option to monitor this component.
Data Included in the Trace Output: You can define individually for each parameter whether
it should be included in the trace output. Each selected parameter will be logged.
Click Apply followed by OK in the confirmation mask (save the new configuration status perma-
nently with the Save icon in the control area).
6.6.7.8 Start Trace Component
You can start a trace component that is currently stopped.
WBM path:
WBM (write access activated with the Padlock icon in the control area?) > Maintenance > Tra -
ces > (double-click) Trace Components > (right-click) selected trace component with red bullet
point > Start Trace Component
The Tra c es tree structure is updated.
6.6.7.9 Stop Trace Component
You can stop a trace component that is currently started.
WBM path:
WBM (write access activated with the Padlock icon in the control area?) > Maintenance > Tra -
ces > (double-click) Trace Components > (right-click) selected trace component with green bul-
let point > Stop Trace Component
The Tra c es tree structure is updated.
>
Certain trace components either cannot be modified, or only support restricted mod-
ification. Trace component elements that cannot be modified are grayed out.