Specifications
Preparing the Board Nur für den internen Gebrauch
A31003-H3580-M103-2-76A9, 01-2009
2-2 HiPath 3000/5000 V8 - HG 1500 V8, Administrator Documentation
hg-02.fm
Configuring the HiPath HG 1500
2.1.2 LED Startup Display
If there is no terminal connected to the V.24 interface of the board, the LEDs at the front of the
HiPath HG 1500 display the main steps of the start routine.
The red LED remains illuminated at the beginning of the boot procedure. Once code loading
has been initiated (see Section 2.1.1, "Firmware Start Routine", step 5), the red power supply
LED flashes once per second. Once the LED has stopped flashing, the boot procedure is com-
plete.
The gateway is operational approximately 30 s after the LED goes out.
2.1.3 Interrupting the Boot Procedure
The boot procedure can be interrupted after the self-test by pressing any key on the terminal
within three seconds of the Press any key to Stop autoboot message appearing on the screen.
If the boot procedure is interrupted in this way, the device switches to a special mode in which
the system may have been configured to request the root administrator’s password. In this
case, enter the password. Access via Boot CLI is granted after logon. With boot CLI, booting
can be manually controlled by entering boot commands and changing the start parameters.
The boot CLI commands are described in the Section D.7, "Start command line".
To repeat the standard boot procedure, press <CTRL>+X.
2.2 Configuring the HiPath HG 1500
Before the HiPath HG 1500 can be administered, an IP address must be assigned to the
board’s LAN1 interface. The IP addresses can be assigned via CLI. Do this by connecting an
appropriate terminal to the HiPath HG 1500’s V.24 interface. Using CLI commands, you can
configure IP addresses, subnet masks and default routers (for a detailed description, see Sec-
tion 2.2.1, "Configuration via CLI Interface").
Once the HiPath HG 1500 has been assigned an IP address and has been rebooted, you can
boot the board WBM via a Web browser in the network (see Chapter 3, "WBM").
>
If a serial terminal is connected, the text "System Running" is displayed on the ter-
minal as soon as the gateway is ready.
>
Information about the IP protocols and port numbers used in HiPath 2000 V1.0 can
be found in Appendix C of the HiPath 2000 Service Manual.