Specifications
hg-08.fm
A31003-H3580-M103-2-76A9, 01-2009
HiPath 3000/5000 V8 - HG 1500 V8, Administrator Documentation
8-9
Nur für den internen Gebrauch
Web Based Simulation Tool
Restrictions
Loading Updates
It only makes sense to load software images and firmware to a real gateway. Although software
images and firmware can be loaded to WST, they cannot be activated.
E-Mail
As the SMTP functionality is not implemented in WST, the function Maintenance > Events > E-
mail cannot be used.
Command Line CLI
You can open a window in WBM for displaying gateway outputs (e.g. traces) and for entering
CLI commands that are sent to the gateway over a V.24 interface.
Although you can display the gateway outputs in this window in WST, you cannot enter CLI
commands.
SNMP
No SNMP functions are available.
RADVision Stack Traces
RADVision stack traces are not possible in WST. The same applies to the configuration of RAD-
Vision stack trace exports and imports.
Reset
Some changes and actions necessitate a restart.
WST does not support the restart functionality. Instead, the simulation is terminated and you
must restart it.
Operating Mode
The operating mode is adopted by the HiPath 3000 system when the board is started. A fixed
value is set by default in WST and can be displayed under Explorers > Basic Settings > System
> Software Build.
Hardware Information
As real HG 1500 boards are not used for simulation, simulated values are entered for all hard-
ware data.
Statistics
As you cannot set up calls with WST, the statistics contain simulated or "root" values.