Using SNMP
The weighting of the individual traps can vary depending on the severity of the event or error
and is described by the following categories:
● Cleared (problem already resolved)
● Indeterminate (no classification possible)
● Critical (critical error)
● Major (major error)
● Minor (minor error)
● Warning (warning only)
● Information (for information only)
General traps, such as MSG_GW_SUCCESSFULLY_STARTED, are sent as "information".
Reboot traps are always "critical", "major" or "minor" errors.
Threshold/resource traps occur as follows: When an event is received, the trap is sent as either
"Warning", "Minor" or "Major". If the trap recurs, reminders are sent (at increasing intervals) with
a weighting that is at least the same or higher than the initial trap. If the event was corrected
(for example, "Link up" or sufficient RAM was provided), the trap is sent with the category
"Cleared".
Type
(SW/HW)
Trap Message
SW MSG_WEBSERVER_MAJOR_ERROR
SW MSG_SSM_NUM_OF_CALL_LEGS_2BIG
SW MSG_SSM_SESSION_CREATION_FAILED
SW MSG_IPNCV_STARTUP_ERROR
SW MSG_IPNCV_STARTUP_SHUTDOWN
SW MSG_IPNCV_INTERNAL_ERROR
SW MSG_IPNCV_MEMORY_ERROR
SW MSG_IPNCV_SIGNALING_ERROR
Table 9-26 Traps for Internal Errors (HG 1500-Specific)