Specifications
hg-09.fm
A31003-H3580-M103-2-76A9, 01-2009
HiPath 3000/5000 V8 - HG 1500 V8, Administrator Documentation
9-41
Nur für den internen Gebrauch
Technical Concepts
Using SNMP
9.8.2 SNMP Functions
The SNMP functions include:
● With MIB browser and standard MIB (based on RFC1213):
– querying and modifying standard MIB 2 parameters
● With MIB browser and private MIB:
– querying and modifying HG 1500’s private MIB parameters
● With HiPath 3000 Manager E:
– defining communities of standard parameters (classes of service)
– defining trap communities and stations to which the traps are sent
– defining the trap level for various trap groups (error sensitivity)
● With trap receiver:
– receiving traps
MIBs also contain a brief commentary explaining the meaning of each parameter.
The following is a list of some parameters:
● mgmt > mib-2 > system > sysUpTime: time since the last HG 1500 startup
● HLB2MIB > siemensUnits > pn > hlb2mib > controlGrouphlb20 > sysSoftwareVersion:
board software release
● mgmt->mib-2->ip->ipRouteTable: HG 1500 routing table
HG 1500 sends SNMP traps (diagnostic and error messages) to the stations configured under
"SNMP > Trap Communities". These messages are transmitted in accordance with the severity
levels set under "SNMP".
Examples of traps generated by HG 1500:
1. Generic traps (cannot be deactivated):
● warm start
● cold start
● authentication failure
2. Enterprise traps (can be configured)
● data init (WARNING - forced data reinitialization)
● memory low (WARNING - memory resources below the threshold)