Specifications

hg-09.fm
A31003-H3580-M103-2-76A9, 01-2009
HiPath 3000/5000 V8 - HG 1500 V8, Administrator Documentation
9-41
Nur für den internen Gebrauch
Technical Concepts
Using SNMP
9.8.2 SNMP Functions
The SNMP functions include:
With MIB browser and standard MIB (based on RFC1213):
querying and modifying standard MIB 2 parameters
With MIB browser and private MIB:
querying and modifying HG 1500s private MIB parameters
With HiPath 3000 Manager E:
defining communities of standard parameters (classes of service)
defining trap communities and stations to which the traps are sent
defining the trap level for various trap groups (error sensitivity)
With trap receiver:
receiving traps
MIBs also contain a brief commentary explaining the meaning of each parameter.
The following is a list of some parameters:
mgmt > mib-2 > system > sysUpTime: time since the last HG 1500 startup
HLB2MIB > siemensUnits > pn > hlb2mib > controlGrouphlb20 > sysSoftwareVersion:
board software release
mgmt->mib-2->ip->ipRouteTable: HG 1500 routing table
HG 1500 sends SNMP traps (diagnostic and error messages) to the stations configured under
"SNMP > Trap Communities". These messages are transmitted in accordance with the severity
levels set under "SNMP".
Examples of traps generated by HG 1500:
1. Generic traps (cannot be deactivated):
warm start
cold start
authentication failure
2. Enterprise traps (can be configured)
data init (WARNING - forced data reinitialization)
memory low (WARNING - memory resources below the threshold)