Specifications
hg-b.fm
A31003-H3580-M103-2-76A9, 01-2009
HiPath 3000/5000 V8 - HG 1500 V8, Administrator Documentation
B-83
Nur für den internen Gebrauch
Traces and Events
Events
Signalling is no longer possible because a session could not be created. The necessary reboot
is executed. An SNMP trap is generated.
MSG_WEBSERVER_MAJOR_ERROR
EventText: %p
Type: Major
Internal error on the web server. A restart is forced since this would affect other web server ac-
tivities. The reboot is executed.
MSG_SNMP_TRAP_COLLECTOR_START_ERROR
EventText: Trap collector could not be started:%n%s
Type: Information
The thread in the trace collector could not be started. Check whether trap port 162 has already
been used elsewhere.
FP_EVT_CRITICAL
EventText: %x %c #%d/%d %x-%x %s
Type: critical
Reboot triggered by a software error.
FP_EVT_MAJOR
EventText: %x %c #%d/%d %x-%x %s#
Type: major
Reboot because resources are exhausted.
FP_EVT_WARNING
EventText: %x %c #%d/%d %x-%x %s
Type: warning
Reboot initiated via the tool.
SIP_REBOOT
EventText: InternalSetUserA
Type: csevMajor
Configuration of the SIP stack failed.