Specifications

hg-b.fm
A31003-H3580-M103-2-76A9, 01-2009
HiPath 3000/5000 V8 - HG 1500 V8, Administrator Documentation
B-85
Nur für den internen Gebrauch
Traces and Events
Events
The problem with the DMA memory limit has been eliminated. Lower memory utilization may
be caused by a lower call volume. An SNMP trap is generated.
MSG_OAM_THRESHOLD_REACHED
EventText: High/Low WaterMark "XXX" [still] reached:
Configured: xxx Current: xxx
Type for this log entry: Warning
A threshold value has been reached (in the flash memory, in the file system memory capacity
or in the netstack IP resources). Details are listed in the event message (percentage limit value,
current value and capacity utilization). An SNMP trap is generated.
EventText: High/Low WaterMark "XXX" no longer reached:
Configured: xxx Current: xxx
Type for this log entry: Cleared
The problem with the threshold value has been eliminated. An SNMP trap is generated.
MSG_OAM_PSU_OR_RPS_OUT_OF_SERVICE
EventText: PSU or RPS [still] out of Service
Type for this log entry: Warning
There is (still) a problem with PSU or RPS. An SNMP trap is generated. Check the PSU and
RPS and replace them if necessary.
EventText: PSU or RPS no longer out of Service
Type for this log entry: Cleared
The problem with the PSU or RPS has been eliminated. An SNMP trap is generated.
MSG_OAM_FAN_OUT_OF_SERVICE
EventText: Fan [still] out of Service
Type for this log entry: Warning
There is (still) a problem with the fan. An SNMP trap is generated. Check the fan and replace
it if necessary.
EventText: Fan no longer out of Service
Type for this log entry: Cleared
The problem with the fan has been eliminated. An SNMP trap is generated.