Specifications

Traces and Events Nur für den internen Gebrauch
A31003-H3580-M103-2-76A9, 01-2009
B-126 HiPath 3000/5000 V8 - HG 1500 V8, Administrator Documentation
hg-b.fm
Events
MSG_HFAM_LIH_PROTOCOL_LIST_ERR
EventText: too many elements in protocol list
Type: Major
Too many elements in the protocol list. Check client setup.
MSG_HFAM_LIH_RETURNED_SOCKET_ERR
EventText: returned socket error
Type: Major
Returned socket error. LAN-side error.
MSG_HFAM_SIH_NO_LOGIN_TIMER_ERR
EventText: timeslot is valid
Type: Major
Login timer for a client could not be started. Start HFA Manager.
MSG_HFAM_SIH_INVAL_TSLOT_PARAM_ERR
EventText: Input Parameter for hfam_sih_send_ts invalid
Type: Major
Input parameter for hfam_sih_send_ts invalid. System-side error.
MSG_HFAM_SIH_CORNET_LONGER_28_ERR
EventText: cannot synthesize CorNet-TS message longer than 28 bytes
Type: Major
Cannot synthesize CorNet-TS messages longer than 28 bytes. System-side error.
MSG_HFAM_MON_NO_MON_TIMER_ERR
EventText: No monitor timer !
Type: Minor
No monitor timer. Start HFA Manager.
MSG_HFAM_REG_LOGIN_NOTREG_ERR
EventText: DL_LOGON_IN received for client not in not_registered state,
subno