Specifications

hg-d.fm
A31003-H3580-M103-2-76A9, 01-2009
HiPath 3000/5000 V8 - HG 1500 V8, Administrator Documentation
D-15
Nur für den internen Gebrauch
The CLI Command Interface
Start command line
LED Indicators During Booting
D.7.1.3 Interrupting the Boot Procedure
The message Press any key to stop auto-boot appears on the terminal during the
boot procedure. The boot procedure can be interrupted within three seconds by pressing any
key on a keyboard connected to the V.24 interface. The session then starts as for the root ad-
ministrator and requests a password.
You can manually control the boot procedure by specifying boot commands and changing the
start parameters. The "Fail" LED flashes for as long as the boot procedure is interrupted.
D.7.2 Controlling the Boot Procedure
D.7.2.1 Boot Commands
The following commands are available for controlling the boot procedure:
LED status Meaning
LED "Fail" flashes
red
Flashing LED indicates that software is being reloaded.
LED "Fail" is off, LED
"Run" is lit
The boot procedure is finished and the board is operational.
Table B-1 LED Indicators During Booting
Command Description
a Enables the TFFS boot line.
b Sets the boot password.
c Changes the start parameters (see also Table 4).
h Shows help on the commands.
l Small "L" prints the Boot logo.
n Displays the network interfaces.
p Displays the start parameters.
t Enables/disables the VLAN tag.
w Loads a software image and copies it to TFFS (per TFTP).
Table B-2 Boot Commands