Specifications

Maintenance Nur für den internen Gebrauch
A31003-H3580-M103-2-76A9, 01-2009
6-4 HiPath 3000/5000 V8 - HG 1500 V8, Administrator Documentation
hg-06.fm
Configuration
You can edit the following fields:
TFTP Server: This field is only available if you select Load via TFTP. Enter the IP address
of the server where the backup file is saved. If the data should be loaded from this server,
activate the radio button beside the input field.
Alternate TFTP Server: This field is only available if you select Load via TFTP. Enter the IP
address of an alternative server where the backup file is saved. If the data should be loaded
from this server, activate the radio button beside the input field.
Remote File Name (PC File System): Enter the file name under which the data is saved.
Browse: This button is only available if you select Load via HTTP. You can search the local
file system for the backup file.
Then click Load. An information window is displayed that you must confirm with OK. The data
is now loaded to the HG 1500 flash memory but it is not yet activated.
The mask Do you want to activate the configuration now? is now displayed.
Use the check boxes and radio buttons below to determine which data is to be loaded. Choose
Select all tables to select all tables for activation. With Deselect all tables none of the tables are
selected. You can also select or deselect the tables individually.
Finally, click Activate Now.
Click the Save icon in the control area and then - if necessary - perform a restart (note the Reset
icon! See also Section 3.2.2, "Icons in the WBM Window’s Control Area").
>
If you would prefer to activate the loaded configuration at a later date, click Do Not
Activate. If you would prefer to activate the configuration data at a later date, click
Job List in the Maintenance menu and activate the job (see Section 6.5, "Job List").
>
LAN speed parameters are neither saved nor restored because each LAN section
may have different LAN speed parameters in certain circumstances. If required,
these parameters must be changed manually.