STUN: STUN mode was set to "AUTOMATIC". A check is made as to whether STUN is
needed for connections with Internet telephony service providers.
STUN: Symmetric NAT identified. STUN is enabled, since this is forced by the "ALWAYS"
mode. If you or your Internet telephony service provider are using an ALG or SBC, this may
possibly be disturbed by STUN. In this scenario please deactivate STUN ("OFF" or "AU-
TO").
STUN: Symmetric NAT identified. STUN is deactivated, since it will probably be of no fur-
ther help. To force the use of STUN please set the STUN mode to "ALWAYS".
LDAP messages:
LDAP server busy
LDAP server not reachable
LDAP server result code
The HG 1500 customer trace log is displayed. If specified, the display is updated every ten sec-
onds.
6.6.4.2 Load via HTTP
You can transfer the log file from HG 3550HG 1500 to the processor via which you administer
the gateway.
WBM path:
WBM (write access activated with the Padlock icon in the control area?) > Maintenance > Tra -
ces > (right-click) Customer Trace Log > Load via HTTP
A log file that can be opened with an editor is stored on your computer.
6.6.4.3 Clear Trace Log
The log file can be deleted from the gateway flash memory. This is useful if you previously per-
formed Load via HTTP.
WBM path:
WBM (write access activated with the Padlock icon in the control area?) > Maintenance > Tra -
ces > (right-click) Customer Trace Log > Clear Trace Log
An important warning is displayed. Click Delete followed by OK in the confirmation mask (save