Data Sheet for Product
s Industry, Inc.
Building Technologies Division
Fire Safety
8 Fernwood Road
Florham Park, NJ 07932
Tel: (973) 593-2600
FAX: (908) 547-6877
URL: www.USA .Si em ens.com/ FI RE
(S
II
-FS)
Printed in U.S .A.
Fire Safety
1577 North Service Road
East Oakville, Ontario
L6H 0H6 / Canada
Tel: [905] 465-8000
URL: www.Siemens.CA
July 2018
Supersedes sheet dated 2/2016
(Rev. 7)
*denotes for required use with Marine-
only installations / applications
Specifications (continued)
Each Model HTRI device has a multi-color LED that
flashes GREEN when operating in Normal; AMBER if
unit is in Trouble condition, and RED to indicate a
change of state.
Field-Device Programmer – Model DPU
Siemens ─ Fire Safety innovative technology allows
HTRI-series intelligent interface modules to be
programmed via the Device Programming / Test
Unit: a compact, portable and menu-driven
accessory that makes programming and testing an
interface device faster, easier and more dependable
than previous methods.
The programmer / tester eliminates the need for
mechanical addressing mechanisms, such as:
program jumpers, DIP switches or rotary dials, since
Model DPU electronically sets the HTRI-series
interface address into the non-volatile memory of
the interface microcomputer-chip.
Vibration, corrosion and other conditions that
deteriorate mechanical addressing mechanisms are
no longer a cause for concern.
The HTRI-series is fitted with screw terminals for
connection to an addressable circuit, and is fully
compatible on the same Siemens FACPs with
Siemens Model `H’-series intelligent detectors; Model
`HMS’-series addressable manual stations, or any
other addressable intelligent modules (e.g. — Model
HZM | -Z or Model HCP | -Z).
Temperature and Humidity Range
Model HTRI-series intelligent interface modules
are UL Listed. Environmental operating
conditions for HTRI-D | -DZ, HTRI-R | -RZ and
HTRI-S | -SZ modules are 32ºF (0ºC) to 120ºF
(49ºC) with a relative humidity of no greater
than 93%, non-condensing.
Electrical Ratings
Current Draw
(Active or Standby)
1.3mA
Relay Ratings, Model HTRI-R | -RZ
Resistive:
4 Amps, 125 VAC
4 Amps, 30 VDC
Electrical Ratings
Relay Ratings, Model HTRI-R | -RZ – (cont.’d)
Inductive:
3.5A, 120 VAC (0.6P.F.)
3.0A, 30 VDC (0.6P.F.)
2.0A, 120 VAC (0.4P.F.)
2.0A, 120 VAC (0.35P.F.)
2.0A, 30 VDC (0.35P.F.)
Mounting Diagram
Models HTRI-D | -DZ, HTRI-R | -RZ and HTRI-S | -SZ
mount directly into a 4-inch (10.2 cm.) square, 2-¼‘’ (5.7
cm.)–deep box back box, or to a user-supplied double-
gang back box. A 5” (12.7 cm.) square, off-white
faceplate is included with each HTRI-series module.
NOTE: For Marine installations, a metal cover faceplate (Model
USCG-HPLATE) is available separately. The faceplate
must be used to protect Siemens HTRI-series interface
modules from receiving radio-frequency interference (RFI).
Details for Ordering
Model
Part
Number
Description
HTRI-R 500-033300 Single Input Module with Relay
HTRI-RZ S54322-F12-A1
Single Input Module with Relay
[ C.O.O.
+
– USA ]
HTRI-D 500-033360 Dual Input Module
HTRI-DZ S54322-F10-A1
Dual Input Module
[ C.O.O.
+
– USA ]
HTRI-S 500-033370 Single Input Module
HTRI-SZ S54322-F13-A1
Single Input Module
[ C.O.O.
+
– USA ]
USCG-
HPLATE
S54319-F22-A1
*Metal Cover Plate for
HTRI Series Interface Modules
Notice: This marketing data sheet is not intended to be used for system design or installation purposes.
For the most up-to-date information, refer to each product’s installation instructions.
+
denotes (C)ountry (o)f (O)rigin