Operation
Field-Device Programmer / Test Unit
Each Remote Alarm Lamp is programmed with the
Siemens field-device programmer / test unit (Model DPU),
which is a compact, portable and menu-driven accessory
for electronically programming and testing Siemens
peripheral modules and devices promptly and reliably.
For instance, the field technician selects the accessory’s
program mode, and enters the desired address. Vibration,
corrosion and other conditions that deteriorate
mechanical-addressing mechanisms are no longer a cause
for concern. Each remote alarm lamp is connected to
Model DPU with the programming cable provided with the
tester. This programming cable
(P/N 110-694927) utilizes
two (2) clip connectors to attach to a
Model ILED-XC | Model ILED-XW lamp.
1
27(: Since the Class X Intelligent Remote Alarm
Lamps are advanced initiating devices,
the
latest Model DPU firmware update is required.
When set in Ctest’ mode, Model DPU will perform a
series of diagnostic tests without altering the address or
other stored data, allowing technicians to determine if
the detector is operating properly.
Each field-device programmer / test unit operates on
AC
power
or rechargeable batteries, providing flexibility
and convenience in the programming / testing of fire-
safety equipment from practically any location.
Additionally, with the use of a Model DPU unit, there is
no longer a concern with any vibration, corrosion and
other deteriorating conditions that compromises the
vitality of a mechanical-addressing mechanism.
Application Note
Models ILED-XC and ILED-XW can also be utilized as a
second accessory of a detector when assigned to respond
to detectors that have remote relay or audible bases.
Temperature and Humidity Range
The Remote Alarm Lamps are UL Listed | ULC Listed.
Environmental operating conditions for each Remote
Lamp is 32ºF (0ºC) to 120ºF (49ºC) with a relative
humidity of no greater than 95%, non-condensing.
Technical Data
23(5$7I1*
92/7$*(5$1*(
9'&±9'&
R(/$7I9(
H80I'I7<
±
QRQFRQGHQVLQJ
C$&7I9(’25C67$1'%<’
&855(170$;
ȝ$
LI1(SI=(6
$0(5I&$1:I5(
G$8*($:*
$:*PD[
$:*PLQ
02'(/
25 7<3(
3$57
180%(5
352'8&7
ILED-XC S54370-B6-A1
IQWHOOLJHQW5HPRWH
/DPS&HLOLQJ
ZLWKEXLOWLQLVRODWRU
ILED-XW S54370-B5-A1
IQWHOOLJHQW5HPRWH
/DPS:DOO
ZLWKEXLOWLQLVRODWRU
DPU 500-033260
'HYLFH3URJUDPPHU
7HV W8QLW
Ceiling | Wall Remote Alarm Lamps
Details for Ordering
1. ILED-XC faceplate
2. Single-gang switchbox
(user supplied)
3. Blank,
single-gang plate
Siemens Industry, Inc.
Building Technologies Division
8 Fernwood Road Florham Park, NJ 07932