Specifications
4 Communication settings and guide of HMI connecting with controller
◎Communication Setting
HMI default communication parameter: 4800, 7, none, 1; station: 1
Inverter internal setting
Code
Name
description
A001 Frequency set
00(VR)/01(Terminal)/02(operator)/03(RS485)/04(OPT 1)/05(OPT 2)
A002
Run set
01(Terminal)/02(operator)/03(RS485) /04(OPT 1)/05(OPT 2)
C71
Baudrate
02(close loop detect)/ 03(2400bps)/ 04(4800bps)/ 05(9600bps)/ 06(19200bps)
C72 Station set 1~32
C73 Data bit 7(7 bit)/8(8 bit)
C74 Parity 00(none)/01(even)/02(odd)
C75 Stop bit 1(bit)/2(bit)
NOTE:A001, A002 must be set 03(RS485)in order to communication with HMI.
◎Supported Device
Device Bit Address Word Address Format Notes
------
P Extend Func 0~50
DD
------
H Extend Func 0~512
DDD
------
F Func Date 0~65535
DDDDD
------
C Func Date 0~65535
DDDD
------
B Func Date 0~999
DDD
------
A Func Date 0~999
DDD
FWD/REW/STOP
(00)FWD/REW/STOP 0
D Write only
FREQ SET ------
(01)FREQ SET 0
D Write only
TerminalPoint State
(02)TerminalPoint State 0~7
D Write only
Surveillance Data ------
(03)Surveillance Data 0~12
DD Read only
Transducer State
(04)Transducer State 0~3
D Read only
Trip Record ------
(05)Trip Record 0~54
DD Read only
Revert ------
(08)Revert 0
D Write only
- 106 -