4 Communication settings and guide of HMI connecting with controller
Default communication: 19200, 8, none, 1; station: 1
RS232 communication
RS485 communication
◎Supported Device
Device
Bit Address
Word Address
Format
Input Relay(
receive external
switch signal)
X0-377 ------ OOO
Output Relay Y0-377 ------ OOO
Auxiliary Relay
M(0-7679)& (8000-8511)
------ DDDD
Step Relay S0-4096 ------ DDDD
Timer Relay T0-511
------
DDD
Counter Relay C0-255
------
DDD
Data Register ------ D0-8511 DDDD
Data Register ------ Z0-15 DD
Data Register ------ V0-15 DD
Timer(Current value)
------ T_Current_Word 0-511 DDD